The role of air conditioning in the diffusion of Sars-CoV-2 in indoor environments: A first computational fluid dynamic model, based on investigations performed at the Vatican State Children's hospital.
Creators
- 1. Boston Children's Hospital
- 2. Scientific Institute for Research, Hospitalization and Healthcare
- 3. Ergon Research, CFD Consultant, Florence, Italy.
- 4. Italian Society of Environmental Medicine, SIMA, Milan, Italy; Staff UNESCO Chair on Health Education and Sustainable Development, Federico II University, Naples, Italy.
- 5. University of Milan
Description
Abstract Background About 15 million people worldwide were affected by the Sars-Cov-2 infection, which already caused 600,000 deaths. This virus is mainly transmitted through exhalations from the airways of infected persons, so that Heating, Ventilation and Air Conditioning (HVAC) systems might play a role in increasing or reducing the spreading of the infection in indoor environments. Methods We modeled the role of HVAC systems in the diffusion of the contagion through Computational Fluid Dynamics (CFD) simulations of cough at the "Bambino Gesu" Vatican State Children's Hospital. Both waiting and hospital rooms were modeled as indoor scenarios. A specific Infection-Index (η) parameter was used to estimate the amount of contaminated air inhaled by each person present in the simulated indoor scenarios. The potential role of exhaust air ventilation systems placed above the coughing patient's mouth was also assessed. Results Our CFD-based simulations of the waiting room show that HVAC air-flow remarkably enhances infected droplets diffusion in the whole indoor environment within 25 s from the cough event, despite the observed dilution of saliva particles containing the virus. At the same time also their number is reduced due to removal through the HVAC system or deposition on the surfaces. The proper use of Local Exhaust Ventilation systems (LEV) simulated in the hospital room was associated to a complete reduction of infected droplets spreading from the patient's mouth in the first 0.5 s following the cough event. In the hospital room, the use of LEV system completely reduced the η index computed for the patient hospitalized at the bed next to the spreader, with a decreased possibility of contagion. Conclusions CFD-based simulations for indoor environment can be useful to optimize air conditioning flow and to predict the contagion risk both in hospitals/ambulatories and in other public/private settings.
Open Access
Publisher Website
Access full text
Publication Details
Journal article
Persistent Identifiers
References
Gao . Transient CFD simulation of the respiration process and inter-person expos...
Read more
007-570-157-448-073
Read more
014-673-558-706-227
Read more
Zhang . Dispersion of coughed droplets in a fully-occupied high-speed rail cabin...
Read more
Gupta . Characterizing exhaled airflow from breathing and talking, Indoor Air. 2...
Read more
Showing first 5 of 18 references.
Scholarly Citations
MeSH Terms
MeSH (Medical Subject Headings) is the NLM controlled vocabulary for indexing biomedical articles.
Click any term to view its definition and hierarchy.