Published July 20, 2004
0 views Journal article Open Access Open Access

Study of Voltammetric Determination of Carcinogenic 1-Nitropyrene and 1-Aminopyrene Using a Glassy Carbon Paste Electrode

  • 1. Charles University in Prague
  • 2. Max Planck Society
  • 3. New Mexico State University
  • 4. UNESCO Laboratory of Environmental Electrochemistry, Department of Analytical Chemistry, Charles University, 128 43 Prague 2, Czech Republic

Description

Linear scan voltammetry (LSV), differential pulse voltammetry (DPV) and voltammetry with adsorptive accumulation (AAV) at a glassy carbon paste electrode (GCPE) based on mixing glassy carbon spherical microparticles with an organic pasting liquid were used for the determination of trace amounts of carcinogenic 1-nitropyrene (1-NP) (the limit of determination around 2.10-5 mol L-1 for LSV and 2.10-6 mol L-1 for DPV) and 1-aminopyrene (1-AP) (the limit of determination around 3.10-6 mol L-1 for LSV, 1.10-6 mol L-1 for DPV and 1.10-7 mol L-1 for AAV) using a Britton-Robinson buffer – methanol mixture as a base electrolyte. The main advantage of this new type of electrode is its full compatibility with media containing a high amount of organic solvent (methanol, acetonitrile)
Enabled by The Lens

Open Access

Licence Attribution (CC BY)
Publisher Website Access full text